Service Telephone£º021-64705533 24-Hour Service Hotline£º15900706965 Mail:info@pingyiao.com
Repsol YPF
   
 
Repsol YPF
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Your present location:HomePage-Products Centre-Repsol YPF
 
 

Repsol Sintetico Comander EHC 46

Description
It is a high performance, fire-resistant hydraulic fluid designed for use in Electro-hydraulic Control steam turbine systems, including those systems which use low tolerance servo-valves. As it is synthetic, any changes from universal fluids to this type should not be made without prior consultation as its compatibility with joints is completely different.
Recommended uses
Control systems of steam turbines in conventional nuclear or heat centres. For example, lubricant in gas turbines.
Qualities
Fire resistance (Mutual-Standard-6930)
Heated circuit test without ignition
Spray ignition (maximum burning persistence) 3 seconds
Anti-wear
Testing in Vickers pump 250 hours:
Hoop weight loss: 5.9 mg.
Pallet weight loss: 3.3 mg
Total loss: 9.2 mg
Four-ball test (40Kg. 1 hour)
Average ring diameter: 0.6 mm
FZG test FZG ¡Ì Load level: 8
Quality Level
FHD fluid. Approved by the principal turbine manufacturers such as Siemens-KWU, BBC, AEG, PARSON, etc
Complies with ASTM-D-4293, ISO-LTCD
Technical Characteristics

Packaging
200 Kg. drums
Hazard Identification
This product is not classified as toxic or hazardous under current legislation.
Handling
Certain minimum precautions to avoid prolonged contact with the skin should be taken when handling. The use of gloves, visors or masks is recommended in order to avoid splashes.
Health and safety hazards
Inhalation: Minimum risk of inhalation as it is a non-volatile product.
Ingestion: Does not provoke vomiting. Drink water. Seek medical assistance.
Contact with Skin: Wash with abundant water and soap.
Eyes: Wash with abundant water.
General measures: Seek medical assistance.
Fire fighting measure
No special measures are required.
Fire control: Foams, dry chemicals, CO2, water spray. Do not apply water jet directly as this may cause the product to spread.
Environmental precautions
Danger of physical contamination in the case of spillage (water flows, coastal areas, the ground, etc.) due to its floating capacity and oily consistency which may cause damage to fauna and flora with which it comes into contact. Avoid its penetration into water containers or outlets.
Decontamination and cleaning: Treat as an accidental oil spillage. Avoid spreading by using mechanical barriers and eliminate using both physical and chemical means.

Unless otherwise specified, the values cited in technical characteristics should be considered as typical.

 
 
   
Copyright © 2001-2010 All Rights Reserved ShangHai PingYiao Trading Co.,Ltd
TEL:(86)21 6470 5533¡¡FAX:(86)21 6470 5533 ext 209 Service Hotline£º15900706965£¨24-hour£© Mail:info@pingyiao.com